Models XW506 XW509 XW507 XW508 XW511i XW514
Digital Input
Channel 4 5
Contact Wet
Sink/Source (NPN/PNP) Sink/Source
Wet Contact On Voltage Level +10 VDC ~ +50 VDC
Off Voltage Level +4 VDC Max.
Dry Contact On Voltage Level
Off Voltage Level
Input Impedance 10 K Ohm
Overvoltage Protection 60 VDC
Intra-module Isolation, Field to Logic 3750 Vrms
Digital Output
Channel 4 5
Contact Open Collector
Sink/Source (NPN/PNP) Sink
Load Voltage +10 VDC ~ +40 VDC
Max. Load Current 200 mA/channel at 25 °C
Overload Protection 1.4 A
Intra-module Isolation, Field to Logic 3750 Vrms
Serial Port
Number of ports RS-232 x 6 RS-232 x 2 RS-422/485 x 1 RS-232 x 8 RS-485 x 4 RS-485 x 8
Interface TxD, RxD, GND TxD, RxD, GND and TxD, RxD, CTS, RTS, GND TxD+/D+, TxD-/D-, RxD+, RxD-, GND TxD, RxD, GND Data+, Data-
Controller 16C550 compatible 16C950 compatible
Speed: 115200 bps Max.
Data bit : 5, 6, 7, 8
Stop bit : 1, 1.5, 2
Parity : None, Even, Odd, Mark, Space
FIFO: Internal 16 bytes for each port FIFO: Internal 128 bytes for each port
Interrupt Shared Interrupt
Intra-module Isolation, Field to Logic 2500 VDC
Mechanical
Dimensions (W x L x H) 66 mm x 82 mm x 13 mm 66 mm x 82 mm x 17 mm 66 mm x 82 mm x 13 mm 66 mm x 82 mm x 14 mm 66 mm x 82 mm x 13 mm
Power Requirements
Input Voltage +5 VDC from PAC
Consumption 0.2 W Max. 0.5 W Max. 0.4 W Max. 0.2 W Max 0.8 W Max. 0.6 W Max.
Environment
Operating Temperature -25 °C ~ +75 °C
Storage Temperature -30 °C ~ +75 °C
Humidity 10 ~ 95% RH, Non-condensing
XW511i     CR 4-port Isolated RS-485 Expansion Board (RoHS)