Trang chủ » PACs » Bộ lập trình nhúng màn hình Win-GRAF OS Windows CE 7.0 CPU Cortex-A8 ICP DAS VP-6208-CE7 CR

Bộ lập trình nhúng màn hình Win-GRAF OS Windows CE 7.0 CPU Cortex-A8 ICP DAS VP-6208-CE7 CR

15″ Win-GRAF Based ViewPAC with Cortex-A8 CPU and WinCE 7.0

Chia sẻ:
Model: VP-6208-CE7 CR
Views: 511

Bộ lập trình nhúng màn hình Win-GRAF OS Windows CE 7.0 CPU Cortex-A8 ICP DAS VP-6208-CE7 CR

The Win-GRAF ViewPAC Series (VP-2208-CE7/VP-3208-CE7/VP-4208-CE7/VP-5208-CE7/VP-6208-CE7) are WinCE7 based Win-GRAF SoftLogic ViewPAC that combine computing and operator interface into a single unit, and provide the perfect solution for integrating HMI, data acquisition and control in an individual PAC.

It is equipped with a Cortex-A8 (720 MHz/1 GHz) CPU, TFT LCD and a variety of connectives including Gigabit Ethernet, USB port, RS-232 and RS-485 interface. I/O expansion is available to use our Ethernet I/O modules and RS-485 I/O modules. Designed for panel mount installation, the front panel is NEMA 4/IP65 rated and can withstand sprayed water, humidity and extreme dust. Designed to operate over a wide -10° C ~ 60° C ambient temperature range, the fanless design offers the ultimate in reliability with no moving parts.

The Win-GRAF ViewPAC are capable of running Win-GRAF (IEC 61131-3 Standard) software to develop logic control, and also provide a free HMI software “eLogger” to edit the HMI by graphical drag and drop the HMI objects, or support M.S. VS 2008 software (VB .NET, C#) to develop HMI and data management applications, and all can exchange data with Win-GRAF applications. So the application’s design is more convenient and practical.

CE7 là một hệ điều hành thời gian thực nhỏ gọn và cứng được sử dụng để nhanh chóng tạo ra các ứng dụng quan trọng và hiệu suất cao theo thời gian. Sử dụng CE7 cho khả năng chạy các phần mềm điều khiển dựa trên PC như Visual Basic .NET, Virtual C #, phần mềm SCADA, SoftPLC, v.v.

  • Máy chủ ftp
  • Máy chủ web
  • Phiên bản nhỏ gọn SQL 3.5
  • .NET Compact Framework 3.5
  • Virtual CE Pro (VECP)

Win-GRAF là một phần mềm phát triển phần mềm, mạnh mẽ, giống như PLC. Nó được cài đặt trên PC với windows 7 hoặc 8 (hoặc phiên bản mới hơn). Nó hỗ trợ chuẩn ngôn ngữ PLC quốc tế – IEC 61131-3 – Sơ đồ bậc thang (LD), Sơ đồ khối chức năng (FBD), Biểu đồ chức năng tuần tự (SFC), Văn bản có cấu trúc (ST), Tập lệnh (IL), phù hợp để phát triển các ứng dụng cho toàn bộ phạm vi của Win-GRAF PAC từ ICP DAS.

Cú pháp mở chuẩn PLC 61131-3 (LD, FBD, SFC, ST, IL)

  •    Sử dụng ST Syntax trong Chương trình FBD hoặc LD
  •    Liên kết dữ liệu kích hoạt sự kiện (Trao đổi dữ liệu giữa các PAC)
  •    Gỡ lỗi / Kiểm soát / Giám sát trực tuyến, Mô phỏng ngoại tuyến
  •    Thay đổi trực tuyến
  •    Các giao thức khác nhau:
  •      – Modbus TCP / UDP, Modbus RTU / ASCII
  •      – Modbus TCP, nô lệ RTU
  •      – DCON …
  •    Rất nhiều chức năng, Khối chức năng, Bảng I / O
  •    Dự phòng (Chỉ dành cho XP-8×38-CE6 PAC)

Lưu ý: Ngoại trừ các mục được lưu ý đặc biệt, tất cả các ứng dụng đều có thể áp dụng cho Win-GRAF PAC (tức là, WP-8xx8, WP-5xx8-CE7, WP-8xx8-CE7, WP-9xx8-CE7, VP-x2x8-CE7, XP-8×38-CE6 PAC).

Thay đổi trực tuyến 

Win-GRAF-Ch9-On-Line-Change

Thay thế dự án đang chạy hiện tại thành một dự án sửa đổi mới mà không dừng dự án.

Đăng nhập HMI

Các cổng nô lệ Modbus RTU / TCP

Win-GRAF-Ch3-Modbus-Slave

Liên kết dữ liệu kích hoạt sự kiện: Win-GRAF-Ch7-Data Binding

I / O từ xa Win-GRAF-Ch8-DCON-Remote-IO

Giải pháp 3G thông minh Win-GRAFWin-GRAF-Ch22-3G-Solution

  • Người dùng có thể giám sát PAC từ xa bằng cách sử dụng mạng không dây 3G hoặc mạng nội bộ
  • Chỉ Máy chủ Giao tiếp WG (hoạt động như Máy chủ Đám mây) mới cần IP công khai (Tên miền hỗ trợ).
  • Các PAC và PC khác kết nối với Máy chủ này không cần IP công cộng.
  • Người dùng có thể giám sát PAC từ xa bằng cách sử dụng mạng không dây 3G hoặc mạng nội bộ.
  • Người dùng có thể sử dụng Bàn làm việc Win-GRAF để kết nối với PAC từ xa để gỡ lỗi / cập nhật chương trình Win-GRAF hoặc cập nhật Trình điều khiển PAC Win-GRAF.
  • PAC có thể chủ động gửi một tệp nhật ký tới PC (WG-Communication-Server)..

 

Hỗ trợ phát triển VS 2008

Win-GRAF PACs hỗ trợ sử dụng VS 2008 (VB.net, C #) để phát triển quản lý dữ liệu và HMI của người dùng các chương trình và có thể trao đổi các biến với các chương trình điều khiển Win-GRAF.

Tạo chức năng và khối chức năng của riêng bạn

Vì một số lý do (như bảo vệ doanh nghiệp, tích hợp với giao thức sản phẩm của riêng bạn, v.v.), bạn có thể phát triển
Các hàm và khối chức năng riêng của VS 2008. Sau đó, bạn có thể sử dụng các hàm và khối chức năng này trong dự án Win-GRAF.

PID Control

Có thể kiểm soát hơn 200 PID trong một PAC.

Models VP-2208-CE7 VP-3208-CE7 VP-4208-CE7 VP-5208-CE7 VP-6208-CE7
LCD
Diagonal Size 7″ (16:9) 8.4″ (4:3) 10.4″ (4:3) 12.1″ (4:3) 15″ (4:3)
Resolution 800 x 480 800 x 600 1024 x 768
Brightness (cd/m2) 400
Contrast Ratio 500 : 1
LED Backlight Life (hrs) 20,000 50,000
Touch Panel 4-wire, resistive type;
light transmission: 80 %
5-wire, resistive type; light transmission: 80 %
LED Indicator 2 (Run, PWR)
System Software
OS Windows CE 7.0
Framework Support .NET Compact Framework 3.5
Embedded Service FTP server, Web server (supports VB script, JAVA script), SQL Compact Edition 3.5
SDK Provided Dll for Visual Studio.Net
Multilanguage Support English, German, French, Spanish, Portuguese, Russian, Italian, Korean, Simplified Chinese, Traditional Chinese
Development Software
Win-GRAF Software Win-GRAF IEC 61131-3 standard
Languages LD, ST, FBD, SFC, IL
Max. Code Size 2 MB
Scan Time 3 ~ 15 ms for normal program
15 ~ 50 ms (or more) for complex or large program
Non-Win-GRAF Options: VS .NET 2008 (VB.NET, C# .NET)
CPU Module
CPU Cortex-A8, 720 MHz Cortex-A8, 1 GHz
SDRAM 512 MB (DDR3)
MRAM 128 KB
Flash (SSD) 256 MB
EEPROM 16 KB
Expansion Flash Memory microSD socket with a
4 GB microSD card (support up to 32 GB)
SD socket with a 4 GB microSD card and a microSD adapter
(support up to 32 GB)
RTC (Real Time Clock) Provides seconds, minutes, hours, day of week, month, year
64-bit Hardware Serial Number Yes, for software copy protection
Dual Watchdog Timers 0.8 second
Rotary Switch Yes (0 ~ 9)
Communication Ports
Ethernet 1 x RJ-45 10/100/1000 Base-T (Auto-negotiating, Auto MDI/MDI-X, LED indicators)
USB 2.0 (host) 2
COM 1 RS-232/RS-485;
2500 VDC isolated
RS-232/RS-485 (DB9 connector); 2500 VDC isolated
COM 2 RS-232 (TxD, RxD, CTS, RTS) /RS-485 (Data+, Data-) (9-wire DB9 connector); 2500 VDC isolated
COM 3 RS-485 (Data+, Data-, GND); 2500 VDC isolated
Audio Earphone-out
Mechanical
Dimensions
(W x H x D) Unit: mm
213 x 148 x 44 249 x 207 x 64 291 x 229 x 54 324 x 255 x 64 381 x 305 x 63
Panel Cut-Out
(W x H) Unit: mm
197 x 133, ± 1 235 x 193, ± 1 277 x 215, ± 1 310 x 241, ± 1 362 x 286, ± 1
Installation Panel Mounting, VESA (75 x 75) Mounting
Ingress Protection Front panel: NEMA 4/IP65
Environmental
Operating Temperature -10 °C ~ +60 °C
Storage Temperature -20 °C ~ +70 °C
Ambient Relative Humidity 10 % ~ 90 % RH (non-condensing)
Power
Input Range +12 VDC ~ +48 VDC
Power from PoE IEEE 802.3af
Isolation 1 kV
Consumption 6 W 7.5 W 13 W 14 W 16 W
Models VP-2208-CE7 VP-3208-CE7 VP-4208-CE7, VP-5208-CE7, VP-6208-CE7
Protocols (Note that certain protocols require optional devices)
NET ID 1 ~ 255, for Modbus TCP/RTU Slave, user-assigned.
Modbus TCP Master A max. of 200 IP links to access/control the devices supporting Standard Modbus TCP Slave protocol.
Modbus RTU/ASCII Master Max. 2 RS-485 ports:
COM1 ~ 2
Max. 2 RS-485 ports:
COM2 ~ 3
Max. 3 RS-485 ports: COM1 ~ 3
Using COM ports to connect other Modbus Slave devices (Like M-7000). Recommend connecting no more than 32 devices in each port for better scan rate.
Modbus RTU Slave Max. 2 RS-485 ports:
COM1 ~ 2
Max. 2 RS-485 ports:
COM2 ~ 3
Max. 3 RS-485 ports: COM1 ~ 3
Using COM ports for connecting SCADA/HMI.
Modbus TCP Slave One Ethernet ports (LAN1) support up to 64 connections. If the PAC uses 1 connection to connect each PC/HMI, it can connect up to 64 PCs/HMIs; If the PAC uses 2 connections to connect each PC/HMI, it can connect up to 32 PCs/HMIs; If one of the Ethernet port malfunctions, the other one can still be used to connect the PC/HMI.
User-defined Protocol COM1 ~ 2 COM2 ~ 3 COM1 ~ 3
Custom protocols can be applied at COM by using Serial communication functions or function blocks.
DCON Remote I/O Max. 2 RS-485 ports:
COM1 ~ 2
Max. 2 RS-485 ports:
COM2 ~ 3
Max. 3 RS-485 ports: COM1 ~ 3
Each port can connect max. 50 nos I-7000 series modules or 50 nos I-87xxxW I/O modules in expansion units (I-87K4, I-87K8, I-87K9, RU-87P8, RU-87P4). Recommend connecting no more than 32 modules in each port for better scan rate.
App Protection Using the unique 64-bit (8 bytes) PAC serial number to generate a protection password by your own algorithm to protect your Win-GRAF application. Then, if someone intend to copy your application in the PAC to another new PAC with the same PAC model, this application will not work properly in that new PAC.
Data Binding Exchange data between ICP DAS Win-GRAF PAC via Ethernet port (LAN1). The data transmission is event triggered. It is much efficient than polling way.
On Line Change For application field that not allowed to stop the Win-GRAF program and wish to run a new program modified a little from the original program.
Modbus RTU I/O When software enables Modbus RTU Master function, the PAC can connect ICP DAS M-7000 and tM series and LC series I/O modules which support Modbus RTU protocol.
Modbus TCP I/O When software enable Modbus TCP Master function, the PAC can connect ICP DAS I-8KE4/8-MTCP, PETL-7000, tPET/tET series I/O modules which support Modbus TCP protocol.
Schedule Control Supports the “Schedule-Control Utility” (free) to implement schedule control. Each PAC can control max. 10 Targets (devices) with different schedule settings in each day / holiday / special day / season / year.
Retain Variables Built-in the fast retain memory that can retain up to 12,000 Win-GRAF variables.
File Access and Data Log The Win-GRAF supports file operation functions to read/write files in the PAC’s micro_SD or flash memory to do data log or file access.
eLogger HMI Support to run HMI program (developed by the eLogger) together with the Win-GRAF logic-control program in the same PAC.
Optional I/O List
GPS GPS-721
* Note: VP-2208-CE7 has no COM3. VP-3208-CE7 has no COM1.
VP-6208-CE7     CR 15″ Win-GRAF Based ViewPAC with Cortex-A8 CPU and WinCE 7.0 (RoHS)

 

Win-GRAF Development Software
Win-GRAF Workbench Win-GRAF Workbench Software (Large I/O Tags) with one USB Dongle.
Power Supply 24 VDC Power Supply with DIN-Rail Mounting (RoHS)
Ethernet Switch 5 to 8 Ports Real-time Redundant Ring Ethernet Switch (RoHS)
5 to 16 Ports Unmanaged Industrial Ethernet Switch (RoHS)
Converter RS-232/422/485 Converter (RoHS)
USB to RS-232/422/485 Converter (RoHS)
TOP HOME