Trang chủ » Module vào/ra tương tự/số kết nối RS-485/Ethernet » Module RS-485 DCON & Modbus 3 kênh đầu vào số (DI) + 3 kênh đầu ra Relay ICP DAS tM-P3R3 CR

Module RS-485 DCON & Modbus 3 kênh đầu vào số (DI) + 3 kênh đầu ra Relay ICP DAS tM-P3R3 CR

3-channel Isolation Digital Input and 3-channel Power Relay Module

Chia sẻ:
Model: tM-P3R3 CR
Views: 1286
Module RS-485 DCON & Modbus 3 kênh đầu vào số (DI) + 3 kênh đầu ra Relay ICP DAS tM-P3R3 CR
The tM-P3R3/tM-PD3R3 provides 3 channels for digital input and 3 channels for relay output, each of which features photocoupler isolation. All output channels are form A type relays, while input is based on sink- or souce-type using a wire connecion. All input channels can be used as 16-bit counters. There are options for configuring power-on and safe digital output values. 4 kV ESD protection and 3750 VDC intra-module isolation are also provided.
  • Tất cả các loại điều khiển bật / tắt
  • Tự động trong công nghiệp
  • Máy móc công nghiệp
  • Tự động hóa tòa nhà
  • Hệ thống thực phẩm và đồ uống
  • Chế tạo chất bán dẫn
  • Hệ thống điều khiển
Model tM-P3R3 tM-PD3R3
Digital Input/Counter
Input Channels 3
Type Wet Contact (Sink, Source) Dry Contact (Source)
Wet Contact On Voltage Level +3.5 VDC ~ 50 VDC
OFF Voltage Level +1 VDC Max.
Dry Contact ON Voltage Level Close to GND
OFF Voltage Level Open
Counters Max. Count 65535 (16-bit)
Max. Input Frequency 100 Hz
Min. Pulse Width 5 ms
Input Impedance 10 kΩ, 0.5 W
Overvoltage Protection 70 VDC
Relay Output
Output Channels 3
Type Power Relay, Form A (SPST N.O.)
Operating Voltage Range 250 VAC or 30 VDC
Max. Load Current 5 A
Operating Time 6 ms
Release Time 3 ms
Electrical Life
(Resistive load)
VDE 5 A @250 VAC 30,000 ops (10 ops/minute) at 75°C
5 A @30 VDC 70,000 ops (10 ops/minute) at 75°C
UL 5 A @250 VAC/30 VDC 6,000 ops
3 A @250 VAC/30 VDC 100,000 ops
Mechanical Life 20,000,000 ops at no load (300 ops/minute)
Power-on Value Yes, Programmable
Safe Value Yes, Programmable
Model tM-P3R3 tM-PD3R3
Communication
Interface RS-485
Format (N, 8, 1), (N, 8, 2), (O, 8, 1), (E, 8, 1)
Baud Rate 1200 ~ 115200 bps
Protocol DCON, Modbus/RTU, Modbus/ASCII
Dual Watchdog Yes, Module (2.3 seconds), Communication (Programmable)
LED Indicators
Power 1 LED as Power Indicator
Isolation
Intra-module Isolation,Field-to-Logic 3750 VDC
EMS Protection
ESD (IEC 61000-4-2) ±4 kV Contact for Each Terminal
±8 kV Air for Random Point
EFT (IEC 61000-4-4) ±4 kV for Power
Power Requirements
Reverse Polarity Protection Yes
Powered from Terminal Block Yes, 10 ~ 30 VDC
Consumption 0.8 W Max. 0.9 W Max.
Mechanical
Dimensions (W x L x H) 52 mm x 98 mm x 27 mm
Installation DIN-Rail Mounting
Environment
Operating Temperature -25 °C ~ +75 °C
Storage Temperature -30 °C ~ +75 °C
Humidity 10 ~ 95% RH, Non-condensing
tM-P3R3     CR 3-channel Isolation DI (Wet) and 3-channel Power Relay Module (RoHS)
tM-7561 CR Isolated USB to RS-485 Converter (RoHS)
tM-7520U CR Isolated RS-232 to RS-485 Converter (RoHS)
tM-7510U CR Isolated RS-485 Repeater (RoHS)
MDR-20-24 CR 24 W Single Output Industrial DIN Rail Power Supply (RoHS)
TOP HOME