ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3133-RCT that gives you access to real-time electric usage for three-phase power measurement. With its high accuracy (<2%, PF=1; Input Current >50 A), this series can be used to both low voltage primary side and medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters monitoring equipment with Rogowski Coil CT is “rope-style” Current Transformer which delivers “Easy Installation” features for large window size (55 ~ 105 mm) and mechanical flexibility for tight space.

It operates over a wide range of input voltages 10 ~ 500 VAC which allows universal compatibility. Also, with 2 channels relay outputs, it can be linked with sirens or lightings for alarm messages. It also supports Modbus RTU, Modbus TCP or CANopen protocols for easy integration.

Model PM-3133-RCT PM-3133-RCT-MTCP PM-3133-RCT-CPS
AC Power Measurement
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Measurement Voltage 10 ~ 500 V
Measurement Current CTØ55 mm (500 A), CTØ80 mm (1000 A)
Measurement Frequency 50/60 Hz
W Accuracy Better than 2% (PF=1; Input Current >50 A)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency, THD
Data Update Rate 1 Second
Communication
Interface RS-485 Ethernet (PoE) CANopen
Protocol Modbus-RTU Modbus TCP CANopen
Baud rate 9600,19200 (default), 38400, 115200; DIP Switch Selectable 125 k (default), 250 k, 500 k, 1 M;
DIP Switch Selectable
Data format N,8,1 (default);
N,8,2; E,8,1; E,8,2; O,8,1; O,8,2
Isolation 3000 VDC 3000 VDC
Alarm Output
Power Relay Form A (Normal Open) × 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC
Power
Input Range +12 ~ 48 VDC +12 ~ 48 VDC or PoE +12 ~ 48 VDC
Power Consumption 2 W
Environment
Temperature Operating Temperature: -20 ~ +70°C / Storage Temperature: -25 ~ +80°C
Ambient Relative Humidity 10% ~ 90% RH, Non-condensing

• Generator monitoring
• Switchgear distribution systems
• Energy Management
• Power quality analysis

RS-485 Interface (Modbus RTU)
PM-3133-RCT500P CR ~ NEW ~ Modbus RTU, 3-phase power meter, 500A Rogowski Coil CT (Inside diameter 55 mm; wire lead 4 m) x 3 ( RoHS)
PM-3133-RCT1000P CR ~ NEW ~ Modbus RTU, 3-phase power meter, 1000A Rogowski Coil CT (Inside diameter 80 mm; wire lead 4 m) x 3 (RoHS)
Ethernet Interface (Modbus TCP)
PM-3133-RCT500P-MTCP CR ~ NEW ~ Modbus TCP, 3-phase power meter, 500A Rogowski Coil CT (Inside diameter 55 mm; wire lead 4 m) x 3 (RoHS)
PM-3133-RCT1000P-MTCP CR ~ NEW ~ Modbus TCP, 3-phase power meter, 1000A Rogowski Coil CT (Inside diameter 80 mm; wire lead 4 m) x 3 (RoHS)
CAN bus Interface (CANopen)
PM-3133-RCT500P-CPS CR ~ NEW ~ CANopen, 3-phase power meter, 500A Rogowski Coil CT (Inside diameter 55 mm; wire lead 4 m) x 3 (RoHS)
PM-3133-RCT1000P-CPS CR ~ Available soon ~ CANopen, 3-phase power meter, 1000A Rogowski Coil CT (Inside diameter 80 mm; wire lead 4 m) x 3 (RoHS)
TOP HOME