Trang chủ » Quản lý năng lượng thông minh » Bộ đo điện thông minh 3 pha bao gồm CT 200A kết nối CANopen ICP DAS PM-3133-240-CPS CR

Bộ đo điện thông minh 3 pha bao gồm CT 200A kết nối CANopen ICP DAS PM-3133-240-CPS CR

Three-phase Smart Power Meter

Chia sẻ:
Model: PM-3133-240-CPS CR
Views: 476

Bộ đo điện thông minh 3 pha bao gồm CT 200A kết nối CANopen ICP DAS PM-3133-240-CPS CR

ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3133 series that gives you access to real-time electric usage for three-phase power measurement. With its high accuracy (<0.5%, PF=1 ), the PM-3133 series can be applied to both low voltage primary side and/ or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input current up to 400 A). It operates over a wide input voltages range 10 ~ 500 VAC which allows worldwide compatibility. And with 2 channels relay outputs, it can be linked with sirens or lightings for alarm messages. It also supports Modbus RTU, Modbus TCP or CANopen protocols for easy integration. You can use CT’s that you currently own with PM-3133P (without CTs) Power Meter. The CT inputs of the PM-3133P can handle a maximum of 333mV of AC current.

• Generator monitoring
• Switchgear distribution systems
• Energy Management
• Power quality analysis

AC Power Measurement
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Loops Three-phase
Input Voltage 10 ~ 500 V
Input Current CTØ24 mm (0.15 A ~ 200 A)
Input Frequency 50/60 Hz
W Accuracy Better than 0.5% (PF=1)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate 1 Second
CT
Includes CTs 3
Type Clip
Max. Current 200 A
Inside Diameter 24 mm
Leading Cable 1.8 m
CANopen
Baud Rate 125 k (default), 250 k, 500 k,
1 M; DIP Switch Selectable
Isolation 3000 VDC
Protocol CANopen
Power
Input Range +12 ~ 48 VDC
Consumption 2 W
Alarm Output Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63 Hz), 5 A @ 30 VDC
Mechanical
Casing Plastic
Dimensions (mm) 33 x 127 x 100 (W x L x H)
Installation DIN-Rail Mounting
Environment
Operating Temperature -20 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
PM-3133-240-CPS     CR CANopen, 3-phase power meter; includes 200A CT (Inside diameter 24 mm; wire lead 1.8 m) x 3 (RoHS)
TOP HOME