Trang chủ » Quản lý năng lượng thông minh » Bộ đo điện thông minh 1 pha (2 Loop) bao gồm CT 60A kết nối Ethernet Modbus TCP ICP DAS PM-3112-100-MTCP CR

Bộ đo điện thông minh 1 pha (2 Loop) bao gồm CT 60A kết nối Ethernet Modbus TCP ICP DAS PM-3112-100-MTCP CR

Single-phase Smart Power Meter

Chia sẻ:
Model: PM-3112-100-MTCP CR
Views: 5010

Bộ đo điện thông minh 1 pha (2 Loop) bao gồm CT 60A kết nối Ethernet Modbus TCP ICP DAS PM-3112-100-MTCP CR

ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3000 series that gives you access to real-time electric usage for single-phase power measurement. With its high accuracy (<1%, PF=1 ), the PM-3000 series can be applied to both low voltage primary side and/or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input current up to 200 A). It operates over a wide input voltages range 10 ~ 300 VAC which allows worldwide compatibility. And with 2 channels relay outputs, it can be linked with sirens or lightings for alarm messages. It also supports Modbus RTU, Modbus TCP or CAN bus protocols for easy integration

• Generator monitoring
• Switchgear distribution systems
• Energy Management
• Power quality analysis

AC Power Measurement
Wiring 1P2W-2CT
Loops Single-phase
Input Voltage 10 ~ 300 V
Input Current CTØ10 mm (0.05 A ~ 60 A)
Input Frequency 50/60 Hz
W Accuracy Better than 0.5% (PF=1)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate 1 Second
CT
Includes CTs 2
Type Clip
Max. Current 60 A
Inside Diameter 10 mm
Leading Cable 1.8 m
Ethernet
Protocol Modbus TCP
Power
Input Range +12 ~ 48 VDC
Consumption 2W
Alarm Output Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VD
Mechanical
Casing Plastic
Dimensions (mm) 33 x 127 x 100 (W x L x H)
Installation DIN-Rail Mounting
Environment
Operating Temperature -20 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
PM-3112-100-MTCP     CR Modbus RTU, 2 loops single-phase Power Meter; includes 60A CT (Inside diameter 10 mm; wire lead 1.8 m) x 2 (RoHS)
TOP HOME