Introduction

Bộ đo điện thông minh 1 pha (2 Loop) 60A ICP DAS PM-3112-100-CPS CR

ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3000 series that gives you access to real-time electric usage for single-phase power measurement. With its high accuracy (<1%, PF=1 ), the PM-3000 series can be applied to both low voltage primary side and/or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input current up to 200 A). It operates over a wide input voltages range 10 ~ 300 VAC which allows worldwide compatibility. And with 2 channels relay outputs, it can be linked with sirens or lightings for alarm messages. It also supports Modbus RTU, Modbus TCP or CAN bus protocols for easy integration

TOP HOME

Model PM-3112 PM-3114 PM-3112-MTCP PM-3114-MTCP PM-3112-CPS PM-3114-CPS
AC Power Measurement
Wiring 1P2W-2CT 1P4W-4CT 1P2W-2CT 1P4W-4CT 1P2W-2CT 1P4W-4CT
Input Voltage 10 ~ 300 V
Input Current CT Φ10 mm (60 A); CTΦ16 mm (100 A); CTΦ24 mm (200 A)
Input Frequency 50/60 Hz
W Accuracy Better than 1% (PF=1)
Starting Current >0.03A ( 60A ), >0.05A (100A ), >0.09A( 200A )
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
Data Update Rate 1 Second
Communication
RS-485 Protocol Modbus-RTU
Baud rate 9600,19200 (default), 38400, 115200;
DIP Switch Selectable
Data format N,8,1
Isolation 2500 VDC
Ethernet Protocol Modbus TCP
CAN Bus Protocol CAN Bus and CANopen
Baud rate 125 k (default), 250 k, 500 k, 1 M;
DIP Switch Selectable
Isolation 2500 VDC
Alarm Output
Power Relay Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC
Power
Input Range +10 ~ 30 VDC +12 ~ 48 VDC +10 ~ 30 VDC
Power Consumption 2 W
Mechanical
Casing Plastic (Flammability UL 94V-0)
Dimensions (W x L x H) 127 mm x 105 mm x 33 mm
Module Installation DIN-Rail Mounting
CT Installation Clip-On
Environment
Operating Temperature -10 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Ambient Relative Humidity 10% ~ 90% RH, Non-condensing
TOP HOME

Ordering Information

PM-3112-100-CPS     CR Modbus RTU, 2 loops single-phase Power Meter; includes 60A CT (Inside diameter 10 mm; wire lead 1.8 m) x 2 (RoHS)