Trang chủ » Quản lý năng lượng thông minh » Bộ đo điện thông minh 3 pha hiển thị LED bao gồm CT 100A kết nối RS-485 Modbus RTU ICP DAS PM-2133D-160P CR

Bộ đo điện thông minh 3 pha hiển thị LED bao gồm CT 100A kết nối RS-485 Modbus RTU ICP DAS PM-2133D-160P CR

3-phase Smart Power Meter with LED Display

Chia sẻ:
Model: PM-2133D-160P CR
Views: 528

Bộ đo điện thông minh 3 pha hiển thị LED bao gồm CT 100A kết nối RS-485 Modbus RTU ICP DAS PM-2133D-160P CR

ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-2133D series that gives you access to real-time electric usage for three-phase power measurement. With its high accuracy (<0.5%, PF=1 ), the PM-2133D series can be applied to both low voltage primary side and/or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input current up to 400 A). It operates over a wide input voltages range 10 ~ 500 VAC which allows worldwide compatibility. This meter has LED display shows power.

• Generator monitoring
• Switchgear distribution systems
• Energy Management
• Power quality analysis

AC Power Measurement
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Loops Three-phase
Input Voltage 10 ~ 500 V
Input Current CTØ16 mm (0.1 A ~ 100 A)
Input Frequency 50 Hz (Range 45 ~ 55 Hz)/60 Hz (Range 55 ~ 65 Hz)
W Accuracy Better than 0.5% (PF=1)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency (45 ~ 65 Hz)
Data Update Rate 1 Second
LED Display Yes, 8-digit
CT
Includes CTs 3
Type Clip
Max. Current 100 A
Inside Diameter 16 mm
Leading Cable 4 m
COM Ports
Ports 1 x RS-485
Baud Rate 9600, 19200 (default), 38400, 115200
Data Format N,8,1; N,8,2; E,8,1; E,8,2; O,8,1; O,8,2
Protocol Modbus RTU
Isolation 3000 VDC
Power
Input Range +85 ~ +264 VAC (277 VAC available)
Consumption 6 W
Mechanical
Casing Plastic
Dimensions (mm) 110 x 115 x 50 (W x L x H)
Installation Panel Mounting
Environment
Operating Temperature -20 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
PM-2133D-160P     CR Modbus RTU, 3-phase power meter; includes 100A CT (Inside diameter 16 mm; wire lead 4 m) x 3 (RoHS)