8-ch Isolated DI (Dry, Wet) and 8-ch Isolated DO (Sink, NPN, 3.5~50 VDC) Module

Chia sẻ:
Model: M-7055-NPN-G CR
Views: 1752

Module RS-485 DCON & Modbus RTU 8 kênh đầu vào số (DI) + 8 kênh đầu ra số (DO) ICP DAS M-7055-NPN-G CR

The I-7055 offers 8 isolated channels for digital input and 8 isolated channels for digital output. Either sink-type or source-type digital input can be selected via wire connections. All digital input channels are also able to be used as 16-bit counters. The I-7055 supports source-type output with short circuit protection. There are options to enable both power-on and safe values. The I-7055D has 16 LED indicators that can be used to monitor the status of the digital input and digital output channels. 4 kV ESD protection and 3750 VDC intra-module isolation are standard. The M-7055 has the same hardware specifications as the I-7055, but provides additional support for the Modbus RTU protocol as well as the DCON protocol.

 

  • Tự động hóa tòa nhà
  • Tự động hóa nhà máy
  • Máy tự động
  • Bảo trì từ xa
  • Chẩn đoán từ xa
  • Kiểm tra trang thiết bị
Models I-7055 I-7055D I-7055-NPN I-7055D-NPN
M-7055 M-7055D M-7055-NPN M-7055D-NPN
Digital Input/Counter
Channels 8
Type Dry Contact Source
Wet Contact Sink/Source
Wet Contact On Voltage Level +10 ~ 50 VDC
Off Voltage Level +4 VDC Max.
Dry Contact On Voltage Level Close to GND
Off Voltage Level Open
Effective Distance
for Dry Contact
500 m Max.
Counters Max. Count 65535 (16-bit)
Max. Input
Frequency
100 Hz
Min. Pulse Width 5 ms
Input Impedance 10 KΩ
Channel-to-Channel Isolation
Overvoltage Protection ±70 VDC
Digital Output
Channels 8
Type Open Source Open Collector
Sink/Source (NPN/PNP) Source Sink
Load Voltage +10 ~ 40 VDC +3.5 ~ 50 VDC
Max. Load Current 650 mA/Channel 700 mA/Channel
Overvoltage Protection 47 VDC 60 VDC
Overload Protection 1.4 A (with short-circuit protection)
Power-on Value Yes
Safe Value Yes
Models I-7055 I-7055D I-7055-NPN I-7055D-NPN
M-7055 M-7055D M-7055-NPN M-7055D-NPN
Communication
Interface RS-485
RS-485 Bias Resistor No (Usually supplied by the RS-485 Master. Alternatively, add a tM-SG4 or SG-785.)
Format N, 8, 1
Baud Rate 1200 ~ 115200 bps
Protocol DCON (for I-7055 series)
Modbus RTU, DCON (for M-7055 series)
Dual Watchdog Yes, Module (1.6 Seconds), Communication (Programmable)
LED Indicator/Display
System LED Indicator Yes, 1 LED as Power/Communication Indicator
I/O LED Indicator Yes, 8 LEDs as Digital Input
& 8 LED as Digital Output Indicators
Yes, 8 LEDs as Digital Input
& 8 LED as Digital Output Indicators
7-Segment LED Display
Isolation
Intra-Module Isolation, Field-to-Logic 3750 VDC
EMS Protection
ESD (IEC 61000-4-2) ±4 kV Contact for each Terminal
±8 kV Air for Random Point
EFT (IEC 61000-4-4) ±4 kV for Power Line
Surge (IEC 61000-4-5) ±3 kV for Power Line
Power
Reverse Polarity Protection Yes
Input Range 10 ~ 30 VDC
Consumption 0.8 W 1.6 W 1.2 W 2.2 W
Mechanical
Dimensions (W x L x H) 72 mm x 123 mm x 35 mm
Installation DIN-Rail or Wall Mounting
Environment
Operating Temperature -25 ~ +75°C
Storage Temperature -40 ~ +85°C
Humidity 10 ~ 95% RH, Non-condensing