Trang chủ » Module vào/ra tương tự/số kết nối RS-485/Ethernet » Module 16 kênh đầu vào biệt lập bộ đếm 16 bit (Counters) ICP DAS I-87053W-A2-G CR

Module 16 kênh đầu vào biệt lập bộ đếm 16 bit (Counters) ICP DAS I-87053W-A2-G CR

16-ch Isolated DI (19~50VDC) Module

Chia sẻ:
Model: I-87053W-A2-G CR
Views: 2669

Module 16 kênh đầu vào biệt lập bộ đếm 16 bit (Counters) ICP DAS I-87053W-A2-G CR

The I-87053W-A2 offers 16 channels for digital input, catering for both dry and wet contact, with an effective distance for dry contact of up to 500 meters. All channels feature photocouple isolation, and can also be used as 16-bit counters. The I-87053W series provides 16 LED indicators that can be used to monitor the DI channel status. 4 kV ESD protection and 3750 VDC intra-module isolation are also provided to enhance noise immunity capabilities in industrial environments. ICP DAS recommends selecting either the “P” or “A2” version of the digital input module for industrial use.
  • Building Automation
  • Factory Automation
  • Machine Automation
  • Remote Maintenance
  • Remote Diagnosis
  • Testing Equipment
CPU Module
Watchdog Timer Yes, Module (1.6 Seconds), Communication (Programmable)
Isolation
Intra-module Isolation 3750 VDC
EMS Protection
ESD (IEC 61000-4-2) ± 4 kV Contact for Each Terminal
±8 kV Air for Random Point
LED Indicators
Status 1 x Power and Communication
16 x I/O
Digital Input
Low Pass Filter Yes
Digital Input/Counter
Channels 16
Type Dry Contact, Wet Contact
Sink/Source (NPN/PNP) Sink, Source
Wet Contact, ON Voltage Level +19 VDC ~ +50 VDC
Wet Contact, OFF Voltage Level +11 VDC Max.
Dry Contact, ON Voltage Level Close to GND.
Dry Contact, OFF Voltage Level Open
Dry Contact, Effective Distance 500 m Max.
Max. Counts 16-bit (65535)
Frequency 100 Hz
Min. Pulse Width 5 ms
Input Impedance 10 kΩ, 1 W
Overvoltage Protection 100 VDC
COM Ports
Ports 1 x RS-485
Baud Rate 1200 ~ 115200 bps
Data Format N, 8, 1
Protocol DCON
Power
Consumption 0.8 W Max.
Mechanical
Dimensions (mm) 30 x 102 x 115 (W x L x H)
Environmental
Operating Temperature -25 ~ +75 °C
Storage Temperature -40 ~ +85 °C
Humidity 10 ~ 95% RH, Non-condensing
Model I-87053W I-87053PW I-87053W-A2
Communication
Interface RS-485
Format N, 8, 1
Baud Rate 1200 ~ 115200 bps
Protocol DCON
Dual Watchdog Yes, Module (1.6 Seconds), Communication (Programmable)
LED Indicators/Display
System LED Indicator 1 LED as Power/Communication Indicator
I/O LED Indicator 16 LEDs as High/Low Alarm Signals
Isolation
Intra-module Isolation, Field-to-Logic 3750 VDC
EMS Protection
ESD (IEC 61000-4-2) 4 kV Contact for Each Terminal
8 kV Air for Random Point
Power
Power Consumption 0.8 W Max.
Mechanical
Dimensions (W x L x H) 30 mm x 102 mm x 115 mm
Environment
Operating Temperature -25 ~ +75°C
Storage Temperature -40 ~ +85°C
Humidity 10 ~ 95% RH, Non-condensing
I-87053W-A2-G     CR 16-ch Isolated DI (Dry, Wet, 19~50VDC) Module (RoHS)
SG-770 CR 7-channel Differential or 14-channel Single-ended Surge Protector (RoHS)
TOP HOME