The I-7188EXD-MTCP is a family of Programmable Device Servers, also known as “Serial-to-Ethernet gateway”, that are designed for linking RS-232/485 devices to an Ethernet network. The I-7188EXD-MTCP also works as a Modbus TCP to RTU gateway that supports most SCADA/HMI communications based on the Modbus TCP protocol.

ICP DAS provides easy-to-use software development tool kits (XServer, Modbus libraries). Users can use them to easily integrate serial devices to have Ethernet/Internet communication ability and through the standard Modbus protocol to communicate with SCADA software (Indusoft, ISaGARF, DasyLab, Trace Mode, Citect, iFix, etc.).

For hardware expansion, the I-7188EXD-MTCP also supports an I/O expansion bus. A cost-effective I/O expansion board with A/D, D/A, D/I, D/O and serial ports is available. Nearly all kinds of I/O functions can be implemented by this bus. But the bus can support only one board. There are more than 50 boards available for I-7188EXD-MTCP, you can choose one of them to expand hardware features.

Features of default Modbus firmware

When you buy an I-7188E -MTCP controller, it already has the default Modbus firmware installed in Flash memory.
The default firmware has the follows features:

  • Converters single Modbus/TCP to multi Modbus/RTU
    The I-7188E -MTCP is a Modbus/TCP gateway. It can easily upgrade many Modbus/RTU devices to have Ethernet communication ability.
  • Supports VxComm technique for every COM port of controllers
    If serial devices don’t support Modbus/RTU, you can still access these devices. But need to install VxComm driver on host PCs and assign a COM port number to link to the remote COM port (of I-7188E -MTCP). After that, serial clients can access these remote serial devices via standard RS-232 functions.
  • Allowed multi-client (or master) access simultaneously
    Different I-7188E -MTCP controller supports different client numbers connect to. Please refer to our FAQ on web for more detail.
    http://www.icpdas.com/faq/7188e/hardware/003.htm
  • Firmware modifiable
    We provide the Modbus SDK allowing users to develop their custom Modbus firmware.

Modbus SDK (in C language)

If the default firmware doesn’t totally suit your requirement. You can use Modbus SDK to modify the default firmware to add extra functions. The Modbus SDK has below features:

  • Supports extra user-defined command protocol (TCP/IP)
    Modbus/TCP protocol supports 2 basic data format (bit and 2-byte integer). It means if clients (or called masters) don’t support Modbus/TCP or you need other format data (for example: string of floating value), I-7188Es (with default firmware) cannot communicate with them. Using this feature, you can develop your special command protocol to transfer any format of data.
  • Register based programming method (easy to use)
    Modbus library supports 4 internal register tables (iMemory_AI, iMemory_AO, iMemory_DI, iMemory_DO), you can use these to store specific information. When Modbus/TCP clients request to I-7188E, Modbus kernel will response information from these 4 tables.
  • Provides user-defined registers
    The 4 internal register tables are all open to users. You need to assign these tables by yourself.
  • Can Iink to Modbus/TCP slave devices
    By using function ModbusTCP_Master2Slave(declared in MBTCP_7E.h),the 7188EX-MTCP can link 8 max . Modbus/TCP device.
  • Can link to Modbus/RTU slave devices
    By using function ModbusMaster2Slave (declared in MBTCP_7E.h), Modbus/RTU devices can be easily integrated to internal registers of I-7188Es. An I-7188E polling every Modbus/RTU devices and put every necessary information to internal registers. Clients only ask the I-7188E to get all information of Modbus/RTU devices. That reduces loading of Clients.
  • Can link to non-Modbus/RTU serial devices
    Some serial devices don’t support Modbus/RTU. We provide functions to let I-7188E -MTCP access serial devices. You can put information to internal registers of it. Thus, the non-Modbus serial devices can also support Modbus/TCP.
  • Supports X boards
    You can choose one suitable Xboard to add on an I-7188EX to be on board I/Os.
  • Xserver SDK compatible
    Modbus SDK is based on Xserver SDK. To lear more programming skills, you can refer demos of Xserver. To get information of demos of Xserver, please refer to CD:\Napdso\7188e\TCP\Xserver\Xserver.htm

Modbus Utility

We provide Modbus tools for Windows 98/SE/NT/2K/XP, it includes:

  1. Modbus Utility
    • On-line configuration via Ethernet
    • On-line help
    • Automatically generate register mapping tables
    • Configuration export/imp
  2. MBRTU
    Modbus/RTU client (with source code in VB6) to diagnostic Modbus/RTU slave devices.
  3. MBTCP
    Modbus/TCP client (with source code in VB6) to diagnostic Modbus/TCP slave devices.
  • Basic application 1: protocol converter
    An I-7188E -MTCP runs a default firmware to become a single Modbus/TCP to multi-Modbus/RTU converter. You can simply use the Modbus Utility to configure the device and then set connection between SCADA , HMI software and the I-7188E.
  • Basic application 2: protocol converter with VxComm technique
    An I-7188E -MTCP is also be able to link to serial devices that don’t support Modbus/RTU. To use this function, you will need to install VxComm driver on host PCs. After installation, you will be able to access the remote COM ports via the standard serial driver.
  • Advanced application 1: Modbus/TCP controller
    Using the Modbus SDK, users can develop their own custom Modbus firmware, allowing extra functions, integration of serial devices and a Xboard to the Modbus/TCP kernel. Thus an I-7188E can become a powerful controller.
  • Advanced application 2: Modbus/TCP controller with VxComm technique
    When an I-7188E -MTCP links same hardware devices as Advanced application 1 link to, if any devices connected to certain COM ports are not integrated into your custom firmware, you are still able to access the COM ports via the standard serial driver. In order to do this, you must install the VxComm driver on the host PCs.
CPU
CPU 80188, 40MHz or compatible
SRAM 512K bytes
Flash Memory 512K bytes
EEPROM 2K Bytes
NVRAM 31 Bytes (battery backup, data valid up to 10 year)
RTC (Real Time Clock) Yes
64-bit Hardware Serial Number Yes
Built-in Watchdog Timer Yes
Communication Interface
COM1 RS-232 (TXD, RXD, RTS, CTS, GND)
COM2 RS-485 (D2+, D2-)
Ethernet Port 10BASE-T NE2000 compatible Ethernet Controller
COM Port Formats
Data Bit 7, 8
Parity Even, Odd, None
Stop Bit 1
LED Indicators
5-Digit 7 Segment LED Display Yes (for I-7188EXD-MTCP only)
System LED Indicator Yes
Hardware Expansion
I/O expansion bus Yes
User defined I/O pins 14 pins
Dimensions
I-7188EX(D)-MTCP 123 mm x 72 mm x 33 mm
Operating Environment
Operating Environment -25°C to +75°C
Storage Temperature -40°C to +80°C
Power
Protection Power reverse polarity protection
Required Supply Voltage +10 to +30VDC (non-regulated)
Power consumption 2W for I-7188EX-MTCP
3W for I-7188EXD-MTCP
I-7188EXD-MTCP     CR Palm-sized Programmable Modbus Gateway with 80188-40 CPU, Modbus Firmware, 512 KB SRAM, RTC, I/O Bus and 7-Segment LED Display (Blue Cover) (RoHS)