Bộ chuyển đổi RTU/ASCII sang HART ICP DAS HRT-711-UTA CR

Modbus TCP/UDP to HART Gateway (for -40 ℃ application)

Chia sẻ:
Model: HRT-711-UTA CR
Views: 2226

Bộ chuyển đổi RTU/ASCII sang HART ICP DAS HRT-711-UTA CR

The HRT-711-UTA Gateway is specially designed for the master device of HART protocol. It allows the Modbus master to access the HART devices. These HART devices may be a transmitter, an actuator and so forth. In addition, we also provide the utility software for users to configure the HRT-711-UTA. By using this module, users can integrate their HART devices into Modbus network easily.

• Industrial Automation
• Factory Automation
• Process Automation
• Etc…

 

COM Ports
Ports RS-232(3 wires)
Ethernet
Ports 10/100Base-TX Ethernet Controller (Auto-negotiating, Auto_MDIX)
HART
Ports 1
Device 2-wired or 4-wired HART devices
Topology Point to Point or Multi-Drop
Data Only Digital Data
Frame Type Short and Long Frame
Burst Mode Supported
Max. HART Device 15
Loop Resistor 250 Ω resistor by Jumper
Isolation UL1577 Spec.
Protocol 2-pin screwed terminal block
Power
Reverse Polarity Protection Power reverse polarity protection, Over-voltage brown-out protection
Input Range Unregulated +10 ~ +30 VDC
Consumption 1 W
Mechanical
Dimensions (mm) 72 x 35 x 121 (W x L x H) Detail
Installation DIN-Rail or Wall Mounting
Environmental
Operating Temperature -25 ~ +75 °C
Storage Temperature -40 ~ +75 °C
Humidity 5% ~ 95% RH, Non-condensing
  • Provide the system and communication configuration of HRT-711-UTA
  • Provide the Modbus address table for HART command data
  • Provide the diagnostic information of HRT-711-UTA module and HART device
  • Provide send / receive HART command to access HART device
  • Provide “Load/Save” module configuration file to apply to other HRT-711-UTA quickly

Modbus Support

Support the following Modbus commands.

Code Name Description
01 Read Coil Status Read the ON/OFF status of discrete outputs in the slave
02 Read Input Status Read the ON/OFF status of discrete inputs in the slave
03 Read Holding Registers Read the binary contents of holding registers in the slave
04 Read Input Registers Read the binary contents of input registers in the slave
05 Force Single Coil Write a single output to either ON or OFF in the slave
06 Preset Single Register Write an integer value into a single register in the slave
15 Force Multi. Coils Write each coil in the sequence of coils to either ON or OFF in the slave
16 Preset Multi. Registers Write a block of contiguous registers in the slave
HRT-711-UTA     CR Modbus TCP/UDP to HART Gateway (RoHS) (for -40 ℃ application)
CA-002 DC connector to 2-wire power cable, 0.3 M
CA-PC09F DB-9 Female connector with plastic cover
CA-0910N DB-9 Female-Female 3-wire Null Modem Cable, 1 M
CA-0915 Male DB-9 to Female DB-9 Cable, 1.5 m
CA-0910F Female DB-9 to Female DB-9 Cable, 1.0 m
CA-0909 Female DB-9 to Female DB-9 connector for tDS-712/tGW-712.
NS-205A CR Unmanaged 5-port Industrial Ethernet Switch with Power Input +12 VDC ~ +56 VDC (RoHS)
NS-205PSE CR Unmanaged Ethernet Switch with 4 PoE Ports and 1 RJ-45 Uplink (RoHS)
FRA05-S12-SU 12 V/0.58 A (max) Power Supply.