Bộ chuyển đổi Modbus RTU/ASCII sang HART ICP DAS HRT-710 CR

Modbus RTU/ASCII to HART Gateway

Chia sẻ:
Model: HRT-710 CR
Views: 3275

Bộ chuyển đổi Modbus RTU/ASCII sang HART ICP DAS HRT-710 CR

The HRT-710 Gateway is specially designed for the master device of HART protocol. It allows the Modbus master to access the HART devices. These HART devices may be a transmitter, an actuator and so forth. In addition, we also provide the software utility, HG_Tool, for module configuration and HART device diagnosis. By using these modules, users can integrate their HART devices into Modbus network easily and quickly.

Model HRT-710 HRT-310
Din Rail Installation Horizontal Upright
HART Signal Standard Enhanced send/receive signal
(For long distance comm.)
Loop Power No Support
(module provides +30V output)
Built-In Resistor 250 Ohm (1/4W) 250 Ohm (1W)
  • Industrial Automation
  • Factory Automation
  • Process Automation
  • Etc..

HRT-710 / HRT-310, a HART master to Modbus slave gateway, is applied to integrate the information from these HART flow meters into the customer’s HMI system. Through the HRT-710 / HRT-310, all of the HART flow meters will be regarded as Modbus slave devices and the HMI system can use the built-in Modbus RTU communication to access these HART flow meters easily.

More than 250 HART device information needs to be integrated to surveillance center. In PC side, uses 3 pieces of PCI cards (VXC-148U, for 24 channels RS-485 expansion). I-2542A and I-2542B (RS-485 to Fiber) are used in every RS-485 channel to extend RS-485 communication distance. There are about 20 pieces of HRT-710 modules used in every RS-485 channel with the different station ID. Through the structure, SCADA or HMI system can integrate all HART device information via Modbus protocol easily and quickly.

COM Ports
Ports RS-232(3 wires) / RS-422 / RS-485
Baud Rate 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Protocol Modbus RTU / Modbus ASCII
HART
Ports 1
Device 2-wired or 4-wired HART devices
Topology Point to Point or Multi-Drop
Data Only Digital Data
Frame Type Short and Long Frame
Burst Mode Supported
Max. HART Device 15
Loop Resistor 250 Ω (1/4W) by Jumper
Isolation UL1577 Spec.
Protocol 2-pin screwed terminal block
Loop Power No
Power
Reverse Polarity Protection Power reverse polarity protection, Over-voltage brown-out protection
Input Range Unregulated +10 ~ +30 VDC
Consumption 1 W
Mechanical
Dimensions (mm) 72 x 35 x 121 (W x L x H) Detail
Installation DIN-Rail or Wall Mounting (Horizontal)
Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +80 °C
Humidity 10% ~ 90% RH, Non-condensing
HRT-710     CR Modbus RTU/ASCII to HART Gateway (RoHS)