Model: GW-7433D-G CR
Views: 584

Bộ chuyển đổi Modbus TCP server/RTU slave sang CANopen master ICP DAS GW-7433D-G CR

“Embedded Internet” and “Embedded Ethernet” are hot topics today. Nowadays the Ethernet protocol becomes a kind of standard for local area network. Via Internet, connectivity is occurring everywhere, from home appliances to vending machines, to testing equipment, to UPS…etc. Using Ethernet for network in industrial area is appealing because the required cabling is already installed.

The GW-7433D is a solution that provides a communication transformation between CANopen protocol and Modbus/TCP & RTU protocol. It solves a mission-critical problem, and connecting an existed CANopen network with Ethernet-base master device as long as this master device supports Modbus/TCP protocol. It enables CANopen networks to be coupled together with the Internet/Ethernet, whereby remote monitoring and controlling is achieved. For CANopen network, the GW-7433D is a CANopen master device. It supports PDO and SDO functions to communicate with slave devices. From the view of Modbus TCP & RTU network, GW-7433D plays a Modbus TCP server or Modbus RTU slave role. It can receive the commands from Modbus TCP client or Modbus RTU master, and process the commands to reply or send the related CANopen data. We provide utility software for users to configure the parameters of CANopen slaves to GW-7433D. When GW-7433D boots up, it will collect the necessary information from all slaves which are predefined in the GW-7433D by using utility. The following figure shows the application architecture for the GW-7433D.

  • Control System
  • Building Automation
  • Factory Automation
  • Distributed data acquisition
  • The Wind Farm application in the Inner Mongolia of China –
    The user applies ICP DAS’s GW-7433D and I-7520 to integrate the large inverters and PLC for the monitor and control of the wind turbines

CPU Module
Watchdog Timer Hardware watchdog
LED Indicators
Status CI LED, MI LED, ERR LED
COM Ports
Ports 1 x RS-232/485, Non-isolated
Baud Rate 1200 ~ 115200 bps
Protocol Modbus RTU Slave
Parity None, Even, Odd
Data Bit 7, 8
Stop Bit 1, 2
Ethernet
Ports 1 x RJ-45, 10/100 Base-TX
Protocol Modbus TCP Server
CANopen
Controller NXP SJA1000T with 16 MHz clock
Ports 1
Baud Rate 10 k ~ 1 M
Isolation 1000 VDC for DC-to-DC, 2500 Vrms for photo-couple
Terminal Resistor Built-in 120Ω
Protocol CiA 301 v4.02
NMT Master
Power
Consumption 2.5 W
Mechanical
Dimensions (mm) 72 x 33 x 122 (W x H x D)
Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
GW-7433D-G     CR  Modbus TCP server & Modbus RTU slave to CANopen Master Gateway (RoHS)