Trang chủ » Truyền thông công nghiệp » Bộ chuyển đổi cổng J1939 sang Modbus TCP Server RTU Slave ICP DAS GW-7238D-G CR

Bộ chuyển đổi cổng J1939 sang Modbus TCP Server RTU Slave ICP DAS GW-7238D-G CR

J1939 to Modbus TCP Server / RTU Slave Gateway

Chia sẻ:
Model: GW-7238D-G CR
Views: 650

Bộ chuyển đổi cổng J1939 sang Modbus TCP Server RTU Slave ICP DAS GW-7238D-G CR

The GW-7238D is a gateway that provides conversion between J1939 and Modbus TCP/RTU protocol. For J1939 network, the GW-7238D supports PDU1, PDU2, broadcast and destination specific type of J1939 messages. For Modbus TCP/RTU network, the GW-7238D is a Modbus TCP server / RTU slave to reply the request from Modbus TCP client / RTU master. Utility software is provided for users to configure J1939 and Modbus TCP/RTU setting in the GW-7238D. The application fields can be diesel power-train applications, In-Vehicle networks for trucks and buses, etc.
The following figure shows the application architecture for the GW-7238D

• Diesel power-train applications
• In-Vehicle networks for trucks and buses
• Truck-Trailer connections
• Fleet management systems
• On Board Diagnostics
• Vehicle Automation\

CPU Module
CPU 80186, 80 MHz or compatible
LED Indicators
Status PWR / J1939 / MODBUS / ERR
COM Ports
Ports 1 x RS-232
1 x RS-485 (Self-turner inside)
Baud Rate 9600, 19200, 38400, 57600, 115200
Protocol Modbus RTU
Ethernet
Protocol RJ-45 with LED indicator / Modbus TCP
J1939
Controller NXP SJA1000T with 16 MHz clock
Transceiver NXP 82C250
Ports 1
Baud Rate 250 k
Isolation 1000 VDC for DC-to-DC, 2500 Vrms for photo-couple
Terminal Resistor Jumper for 120 Ω terminal resistor
Specification ISO-11898-2, CAN 2.0A and CAN 2.0B
Power
Consumption 2 W
Mechanical
Dimensions (mm) 122 x 72 x 33 (L x W x H)
Installation DIN-Rail
Environmental
Operating Temperature -25 ~ +75 ℃
Storage Temperature -30 ~ +80 ℃
Humidity 10 ~ 90% RH, Non-condensing
  • Provide Modbus network configuration interface
  • Provide J1939 network configuration interface – Network Address / Device Name, etc
  • Provide J1939 Input / Output configuration interface
  • Provide Modbus monitoring interface

Comparison Table

ICP DAS Fieldbus Gateways Comparison Table:
Model Support Protocol Comm. Interface
GW-7228 J1939 Modbus RTU Slave RS-232
RS-422
RS-485
GW-7433D CANopen Master Modbus TCP server/RTU Slave RS-232
RS-485
Ethernet
I-7231D CANopen Slave DCON Master RS-232
RS-485
I-7232D CANopen Slave Modbus RTU Master RS-232
RS-485
I-7241D DeviceNet Slave DCON Master RS-232
RS-485
I-7242D DeviceNet Slave Modbus RTU Master RS-232
RS-485
I-7243D DeviceNet Master Modbus TCP server Ethernet
GW-7243D DeviceNet Slave Modbus TCP/RTU/ASCII Master RS-232
RS-485
Ethernet
GW-7552 PROFIBUS DP-V0 Slave Modbus RTU/ASCII
Master/Slave
RS-232
RS-422
RS-485
GW-7553 PROFIBUS DP-V0 Slave Modbus TCP/RTU/ASCII Master/Slave RS-232
Ethernet
HART-710 HART Master Modbus RTU/ASCII Slave RS-232
RS-422
RS-485
GW-7238D-G     CR J1939 to Modbus TCP Server / RTU Slave Gateway included CA-0910 cable(RoHS)