Trang chủ » Truyền thông công nghiệp » Bộ chuyển đổi Gateway DNP3 Master sang Modbus TCP Server ICP DAS DNP-211

Bộ chuyển đổi Gateway DNP3 Master sang Modbus TCP Server ICP DAS DNP-211

DNP3 Master to Modbus TCP Server Gateway

Chia sẻ:
Model: DNP-211 CR
Views: 771

Bộ chuyển đổi Gateway DNP3 Master sang Modbus TCP Server ICP DAS DNP-211

Distributed Network Protocol 3 (DNP3) is a set of communications protocols used between components in process automation systems. Its main use is in utilities such as electric and water companies. It was developed for communications between various types of data acquisition and control equipment. It plays a crucial role in SCADA systems. It is primarily used for communications between a master station and Remote Terminal Units (RTUs) or Intelligent Electronic Devices (IEDs).

DNP-211 is a solution that provides a communication transformation between DNP3 and Modbus TCP protocol. It can connect an existed DNP3 network with Ethernet-base master device as long as this master device supports Modbus TCP protocol. For DNP3 network, the DNP-211 is a DNP3 master device. It supports several commonly data group and variation communicate with slave devices. From the view of Modbus TCP network, DNP-211 plays a Modbus TCP server role. It can receive the commands from Modbus TCP client and process the commands to reply or send the related DNP3 data. All the DNP3 I/O data and Modbus address mapping can be configured via DNP-211 utility.

Software
OS Linux Kernel 3.2.14
Protocol Modbus TCP server:
• Function:1, 2, 3, 4, 15, 16
• connection:Max. 16 Modbus TCP clients

DNP3 master:
• connection:Max. 32 DNP3 Outstations
• Data Group:1, 10, 12, 20, 30, 40, 41
• Data Points:
DI: 8192
DO: 8192
Count: 2048
AI: 2048
AO: 2048

Service SFTP server

 

Main Unit
CPU Cortex-A8, 1 GHz
System Memory 512 MB DDR3 SDRAM
Real Time Clock Yes (Provide seconds, minutes, hours, day of week, month, year)
Watchdog Timer Yes, Dual Watchdog Timer

 

Display
Signal VGA (Analog RGB)

 

LED Indicators
Status 1 x PWR(Power)
1 x RUN(Running)
1 x L1
1 x L2
1 x L3

 

COM Ports
Ports 1 x RS-232 (Console, Non-isolated)
1 x RS-232, Non-isolated
1 x RS-485, Non-isolated
1 x RS-485 (2500 VDC, Isolated)

 

Ethernet
Ports 2 x RJ-45, 10/100/1000 Base-TX

 

USB
Ports 2
Specification USB 2.0 (Host)

 

Power
Input Range +12 VDC ~ +48 VDC
Consumption 4.8 W

 

Mechanical
Casing Metal
Dimensions (mm) 35 x 167 x 119 (W x L x H)
Installation DIN-Rail or Wall Mounting (optional)

 

Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -40 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
DNP-211     CR  DNP3 Master to Modbus TCP Server Gateway (RoHs)