The CL-200 series of data logger devices can be used to record CO, CO2, NH3, H2S, HCHO, TVOC, temperature, humidity and dew point information, including the date and time stamps, and are able to store up to 450,000 downloadable records. Real-time data can be accessed from the CL-200 data logger from anywhere and at any time using the free Windows software, the Iso App, or the Android App, as long as they are connected to the same local network as the data logger. Support is provided for common industrial protocols such as DCON, Modbus RTU, and Modbus TCP, as well as the emerging machine to-machine (M2M)/)IoT (Internet of Things) connectivity protocol – MQTT. The CL-200 data logger can be connected via widely used communication interfaces including RS-485, Ethernet and PoE, meaning that the device can be easily integrated into existing HMI or SCADA systems, ensuring trouble-free maintenance in distributed control systems.

Supports the MQTT Protocol for IoT Applications

Multi-platform Remote Access Software
Real-time data from the CL-200 data logger can be accessed from anywhere and at any time using the DL300 Utility, the iOS or Android App, or via a regular web browser, as long as they are connected to the same local network as the data logger.

Simple and Powerful CL-200-E Utility
The DL300 Utility can be used to configure the modules, monitor real-time data, group CL-200-E modules so that the status of distribution groups can be viewed and managed. The utility also allows the log data to be downloaded and exported to a .CSV file that can then be imported into any industry-standard software or spread sheet for analysis.

The DL-300 Utility is a powerful tool that is designed for configuring the modules, monitoring real-time data, grouping DL-300 and CL-200 modules to view and manage the status of distribution groups, downloading log data, which can be exported to a CSV file that can then be imported into any industry-standard software or spreadsheet for analysis.

  • Transportation of Food or Pharmaceuticals
  • Food and Beverage Industry (HACCP)
  • Blood Stations and Pharmacies
  • Building and Energy Management
  • Warehouse Management
  • Museums, Archives and Galleries

Indoor or Underground Parking Lot Automatic Monitoring Solution

The air quality automation system for indoor or underground parking lot can use the CL-200 series modules to monitor the health and safi ty information, such as CO, CO2, temperature, humiditym, dew point, and more…

HCHO (Formaldehyde) / VOC Detector Automatic Solution
The HCHO/VOC detector provides an instantaneously warning of toxic formaldehyde, which can be found in a plywood factory, furniture factory and new interior remodelling house commonly.

 

Model CL-201-E CL-202-E CL-203-E CL-204-E CL-205-E CL-206-E CL-207-E CL-208-E
System
CO Alarm Yes Yes
CO2 Alarm Yes Yes
HCHO Alarm Yes Yes
TVOC Alarm Yes Yes
NH3 Alarm Yes
H2S Alarm Yes
RH/Temperature Alarm Yes
Real Time Clock Yes
Data Logger Yes, up to 450,000 records
Relay Output Form A×1, SPST
30 VDC @ 16 A or 250 VAC @ 16 A
Interface RS-485/Ethernet
Electrical
Powered from Terminal Block +12 to +48 VDC
Power Consumption Non-PoE 1.5 W (Max.) 1.5 W (Max.) 1.6 W (Max.) 1.9 W (Max.) 1.6 W (Max.) 1.6 W (Max.) 1.9 W (Max.) 1.9 W (Max.)
PoE 1.6 W (Max.) 1.6 W (Max.) 1.7 W (Max.) 2.0 W (Max.) 1.7 W (Max.) 1.7 W (Max.) 2.0 W (Max.) 2.0 W (Max.)
Mechanical
Installation Ceiling Mounting/Wall Mounting
Protection Class IP20
Dimensions (D x H) Ø 150 mm x 53 mm
Environment
Operating Temperature 0 to +50°C
Storage Temperature -1 ppm
Humidity 10 to 90% RH, Non-condensing
Model CL-201-E CL-202-E CL-203-E CL-204-E CL-205-E CL-206-E CL-207-E CL-208-E
CO Measurement
Range 0 to 1000 ppm (Electrochemical) 0 to 1000 ppm
(Electrochemical)
Resolution 1 ppm 1 ppm
Accuracy ±5% of
measured value
±5% of measured value
Response Time 30 seconds 30 seconds
Warm-up Time 300 seconds 300 seconds
CO2 Measurement
Range 0 to 9999 ppm (NDIR)
Resolution 1 ppm
Accuracy ±40 ppm ±3% of measured value
Response Time 120 seconds
Warm-up Time 5 minutes
NH3 Measurement
Range 0 to 100 ppm
(Electrochemical)
Resolution 1 ppm
Accuracy ±5% of
measured value
Response Time < 120 Sec
Warm-up Time 180 Sec
H2S Measurement
Range to 100 ppm
(Electrochemical)
Resolution 1 ppm
Accuracy ±5% of
measured value
Response Time < 120 Sec
Warm-up Time 180 Sec
HCHO Measurement
Range 0 ppb to 2000 ppb (Electrochemical) 0 ppb to 2000 ppb (Electrochemical)
Resolution 1 ppb 1 ppb
Accuracy
Response Time ≤60 seconds ≤60 seconds
Warm-up Time 180 seconds 180 seconds
TVOC Measurement
Range 0 ppb to 60000 ppb (MEMS Metal Oxide) 0 ppb to 60000 ppb
(MEMS Metal Oxide)
Resolution 1 ppb 1 ppb
Accuracy ±15% ±15%
Response Time 60 seconds 60 seconds
Warm-up Time 180 seconds 180 seconds
Temperature Measurement
Range -10 to +50°C
Resolution 0.1°C
Accuracy ±0.6°C
Relative Humidity Measurement
Range 0 to 100% RH, Non-condensing
Resolution 0.1% RH, Non-condensing
Accuracy ±5% RH, Non-condensing
Dew Point
Range Calculated using temperature and relative humidity
Resolution 0.1°C

CL-2xx-E + RJ45 Cable:
CL-2xx-E (Ethernet Type) are with optional angle-bent RJ45 cable to smoothly install the Ethernet plug in the hole of the ceiling-mounted.

CL-206-E     CR H2S/Temperature/Humidity/Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
EWB-C150 External Wall Box for CL-200 series
CA-RJ45-04 RJ45 Cable, Male-Female, 30cm (90º)