Thiết bị đo điện thông minh 3 pha 1000A RS-485 Modbus RTU ICP DAS PM-3133i-RCT1000P CR

Modbus RTU, Isolated 3-phase power meter, 1000A Rogowski Coil CT

Chia sẻ:
Model: PM-3133i-RCT1000P CR
Views: 855

ICP DAS brings the most powerful, cost-effective Smart Power Meters PM-3133i-RCT series that access real-time electric usage for three-phase power measurement. The PM-3133i-RCT series can be applied to the low voltage primary side and/or medium/high voltage secondary side, and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipment in real-time under operation. In addition to its compact size and cost performance, the additional Rogowski Coil CT is suitable for high current measurements from 500A to 4000A, large wire diameters (e.g. busway conductor), and for installation in tight spaces. Built-in AC isolator protection, this means total isolation between the AC measurement side and the control side. It operates over a wide input voltages range 10 ~ 600 VAC which allows worldwide compatibility.

• Generator monitoring
• Switchgear distribution systems
• Energy Management

AC Power Measurement
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Loops 3-phase: 1
1-phase:
3 @ 1P2W-1CT
1 @ 1P3W-2CT
Input Voltage 10 ~ 600 V
Input Current PM-3133i-RCT500P: CTØ55 mm (5 A ~ 500 A)
PM-3133i-RCT1000P: CTØ80 mm (5 A ~ 1000 A)
PM-3133i-RCT2000P: CTØ105 mm (5 A ~ 2000 A)
PM-3133i-RCT4000P: CTØ185 mm (5 A ~ 4000 A)
Input Frequency 50/60 Hz
W Accuracy Better than 2% (PF=1)
Condition:
Input current > 50A; (For -500P, -1000P)
Input current > 200A; (For -2000P, -4000P)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent
Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate 1 Second
COM Ports
Ports 1 x RS-485
Baud Rate 9600, 19200 (default), 38400, 115200; DIP Switch Selectable
Data Format N,8,1 (default); N,8,2; E,8,1; E,8,2; O,8,1; O,8,2
Protocol Modbus RTU
Isolation 3000 VDC
Power
Input Range +12 ~ 48 VDC
Consumption 2 W
Mechanical
Casing Plastic
Dimensions (mm) 33 x 127 x 100 (W x L x H)
Installation DIN-Rail Mounting
Environment
Operating Temperature -20 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
PM-3133i-RCT1000P     CR  Modbus RTU, Isolated 3-phase power meter, 1000A Rogowski Coil CT (Inside diameter 80 mm; wire lead 4 m) x 3 (RoHS)