Bộ đo điện thông minh 3 pha 60A Ethernet Modbus TCP ICP DAS PM-3133-100P-MTCP CR

Modbus TCP, 3-phase power meter; includes 60A CT

Chia sẻ:
Model: PM-3133-100P-MTCP CR
Views: 822

ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3133 series that gives you access to real-time electric usage for three-phase power measurement. With its high accuracy (<0.5%, PF=1 ), the PM-3133 series can be applied to both low voltage primary side and/ or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input current up to 400 A). It operates over a wide input voltages range 10 ~ 500 VAC which allows worldwide compatibility. And with 2 channels relay outputs, it can be linked with sirens or lightings for alarm messages.

• Generator monitoring
• Switchgear distribution systems
• Energy Management

AC Power Measurement
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Loops 3-phase: 1
1-phase:
3 @ 1P2W-1CT
1 @ 1P3W-2CT
Input Voltage 10 ~ 500 V
Input Current PM-3133-005P-MTCP: CTØ10 mm (0.05 A ~ 5 A)
PM-3133-100P-MTCP: CTØ10 mm (0.05 A ~ 60 A)
PM-3133-100-MTCP: CTØ10 mm (0.05 A ~ 60 A)
PM-3133-160P-MTCP: CTØ16 mm (0.1 A ~ 100 A)
PM-3133-160-MTCP: CTØ16 mm (0.1 A ~ 100 A)
PM-3133-240P-MTCP: CTØ24 mm (0.15 A ~ 200 A)
PM-3133-240-MTCP: CTØ24 mm (0.15 A ~ 200 A)
PM-3133-360P-MTCP: CTØ36 mm (0.3 A ~ 300 A)
PM-3133-400P-MTCP: CTØ36 mm (0.3 A ~ 400 A)
Input Frequency 50/60 Hz
W Accuracy Better than 0.5% (PF=1)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate 1 Second
Relay Output
Channels 2
Type Power Relay
Contact Rating Form A:
5 A @ 250 VAC
5 A @ 30 VDC
Ethernet
Ports 1x RJ45, 10/100 Base-TX
PoE Yes
Protocol Modbus TCP
Power
Input Range +12 ~ 48 VDC or PoE
Consumption 2 W
Mechanical
Casing Plastic
Dimensions (mm) 33 x 127 x 100 (W x L x H)
Installation DIN-Rail Mounting
Environment
Operating Temperature -20 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing
PM-3133-100P-MTCP     CR Modbus TCP, 3-phase power meter; includes 60A CT (Inside diameter 10 mm; wire lead 4 m) x 3 (RoHS)
TOP HOME